Reference Guide
Debugging and Diagnostics | 257
The S6000 supports thirty-two 40G ports or 104 physical ports maximum (mix of 10G and 40G) are
allowed ninety-six10G ports or twenty-four 40G ports, and eight fixed 40G ports. Ports 4, 12, 20, 28, 100,
108, 116, and 124 are the ports where fanout configuration is not allowed. That is, fan-out is not supported
on the top four ports of the first four columns and the last four columns of the table above. Ports are
numbered from 0 and spaced in multiples of four (in order to accommodate fanout) up to 124 ports.
Table 13-3. (S6000) Internal-Userport-Mapping- (When All Ports are in 40gig Mode)
Internal Port
Numbering
User Port
-Numbering Mode
xe0
0
40G/10G
xe1 4 Fixed 40G Port
xe2 8 40G/10G
xe3 12 Fixed 40G Port
xe4 16 40G/10G
xe5 20 Fixed 40G Port
xe6 24 40G/10G
xe7 28 Fixed 40G Port
xe8 32 40G/10G
xe9 36 40G/10G
xe10 40 40G/10G
xe11 44 40G/10G
xe12 48 40G/10G
xe13 52 40G/10G
xe14 56 40G/10G
xe15 60 40G/10G
xe16 64 40G/10G
xe17 68 40G/10G
xe18 72 40G/10G
xe19 76 40G/10G
xe20 80 40G/10G
xe21 84 40G/10G
xe22 88 40G/10G
xe23 92 40G/10G
xe24 96 40G/10G
xe25 100 Fixed 40G Port
xe26 104 40G/10G
xe27 108 Fixed 40G Port
xe28 112 40G/10G
xe29 116 Fixed 40G Port