Reference Guide
Debugging and Diagnostics | 249
Temperature displays Celsius units.
Temperature via SNMP:
OID Name: chSysPortXfpRecvTemp
SNMP OID: .1.3.6.1.4.1.6027.3.10.1.2.5.1.7
1. Obtain the temperature of connected optics using a SNMP walk to this OID.
2. The measured power is always in Celsius.
Note:
• The Value of “1000000” indicates the power reading is not supported (for example, copper
optics power reading is not supported).
• The value of “65535” indicates optics is not present.
• Enabling
enable optic-info-update interval command updates both power and temperature
readings.