Reference Guide

242 | Debugging and Diagnostics
www.dell.com | support.dell.com
Figure 13-7. show diag stack-unit Command Example
FTOS#show diag stackunit 0
Diag status of Stackunit member 0:
--------------------------------------------------------------------------
Stackunit is currently offline.
Stackunit level0 diag issued at Thu May 09, 2013 01:04:35 PM.
Current diag status : Unit diags are done.
Total number of diags : 26
Number of diags performed : 26
Number of diags passed : 23
Number of diags failed : 3
Number of diags pending : 0
Last Test executed : USBHOSTCONTROLLERACCESSTEST
Duration of execution (Total) : 1 min 50 sec.
Diagnostic test results located: flash:/TestReport-SU-0.txt
Last notification received at Thu May 09, 2013 01:06:25 PM
--------------------------------------------------------------------------
--------------------------------------------------------------------------
Device slave_cpld, address=0x33 reg=0x6 size=1
Device slave_cpld, address=0x33 reg=0x7 size=1
Device mstr_cpld, address=0x32 reg=0x10 size=1
Device mstr_cpld, address=0x32 reg=0x11 size=1
Device mstr_cpld, address=0x32 reg=0x8 size=1
*******************************S6000 DIAGNOSTICS*******************************
Board : S6000 Dell Networking
CPU Version : Intel Centerton Processor
Stack Unit Board Temp : 33 Degree C
Stack Unit Number : 0
Board Service Tag : STG1234
System Cpld Rev : 0xa
Master Cpld Rev : 0xc
Slave Cpld Rev : 0xa
Image Build Version : 9.0(2.0)
-------- Offline Test Statistics --------
Total : 26
Passed : 23
Failed : 3
Stop reason : Diags completed
-------- Failed tests (level, test ID, times) --------