Administrator Guide
MIB Support for CAM
Dell EMC Networking provides a method to retrieve the CAM usage information. The following table lists the related MIB objects:
Table 115. MIB Objects for CAM
MIB Object OID Description
camUsageL2Pip
eLine
1.3.6.1.4.1.6027.3.7.1.1.2.1.11 Contains information about the pipe line number of the
chip on the layer 2 switch where CAM is located.
camUsageL3Pip
eLine
1.3.6.1.4.1.6027.3.7.1.1.3.1.19 Contains information about the pipe line number of the
chip on the layer 3 switch where CAM is located.
camUsageL3Ing
QosUsed
1.3.6.1.4.1.6027.3.7.1.1.3.1.12.stack-unit.port-pipe.pipe-line Contains information about the total CAM size allocated
to layer 3 ingress QOS.
camUsageL3Ing
AclUsed
1.3.6.1.4.1.6027.3.7.1.1.3.1.16.stack-unit.port-pipe.pipe-line Contains information about the total CAM size allocated
to layer 3 ingress ACL.
camUsageL3Eg
rAclUsed
1.3.6.1.4.1.6027.3.7.1.1.3.1.18.stack-unit.port-pipe.pipe-line Contains information about the total CAM size allocated
to layer 3 egress ACL.
camUsageL2Ing
AclUsed
1.3.6.1.4.1.6027.3.7.1.1.2.1.4.stack-unit.port-pipe.pipe-line Contains information about the total CAM size allocated
to layer 2 ingress ACL.
camUsageL2Eg
rAclUsed
1.3.6.1.4.1.6027.3.7.1.1.2.1.10.stack-unit.port-pipe.pipe-line Contains information about the total CAM size allocated
to layer 2 egress ACL.
NOTE: The last three digits of these OIDs correspond to the stack-unit, port-pipe, and pipe-line respectively. The values
corresponding to these fields are incremented by one before being displayed in the
snmp walk
output. As a result, the
stack-unit number, the port-pipe number, and the pipe-line number starts from 2 instead of 1.
Viewing the CAM MIB
• To view the CAM MIB generated by the system, use the following commands.
snmpwalk -c public -v 2c 10.16.210.24 1.3.6.1.4.1.6027.3.7.1.1.3.1.12
SNMPv2-SMI::enterprises.6027.3.7.1.1.3.1.12.1.1.1 = INTEGER: 0
snmpwalk -c public -v 2c 10.16.210.24 1.3.6.1.4.1.6027.3.7.1.1.3.1.16
SNMPv2-SMI::enterprises.6027.3.7.1.1.3.1.16.1.1.1 = INTEGER: 1
snmpwalk -c public -v 2c 10.16.210.24 1.3.6.1.4.1.6027.3.7.1.1.3.1.18
SNMPv2-SMI::enterprises.6027.3.7.1.1.3.1.18.1.1.1 = INTEGER: 8
MIB Support for PFC Storm Control
Dell EMC Networking provides MIB objects to display the information for PFC Storm Control. The OIDs specific to PFC Storm Control are
appended to the dellNetFpStatsMib. These statistics can also be obtained by using the CLI commands:
show storm-control pfc status
stack-unit <> port-set <>
and
show storm-control pfc statistics stack-unit <> port-set <>
. The following table lists the related
MIB objects, OID and description for the same:
Table 116. MIB Objects to Display the Information for PFC Storm Control
MIB Object OID Description
dellNetFpPfcStormControl 1.3.6.1.4.1.6027.3.27.1.21 Index for the table.
dellNetFpPfcStormControlStatus 1.3.6.1.4.1.6027.3.27.1.21.1 Storm control status.
dellNetFpPfcStormControlStatusTable 1.3.6.1.4.1.6027.3.27.1.21.1.1 Table to show counters of Pfc Storm-
Control on per port per priority basis.
Simple Network Management Protocol (SNMP) 801