Users Guide

Switch validation
38 Dell EMC Networking OS9 Switch Configuration Guide for VxRail 4.5
8.1.5 show vrrp brief
In this deployment, VRRP is configured on the in-band management VLAN, 1611, to provide gateway
redundancy for management traffic. The output from the show vrrp brief command shows the local and
virtual IP addresses and whether the switch is in the master or backup role. The switch configured with the
largest priority value, shown in the Pri column, becomes the master.
S5048F-Leaf1A#show vrrp brief
Interface Group Pri Pre State Master addr Virtual addr(s) Description
--------------------------------------------------------------------------------
Vl 1611 IPv4 11 150 Y Master 172.16.11.253 172.16.11.254
Note: For the dual switch without VLT topology, the output is identical to that shown above. For the single
switch topology, this command is not applicable.
8.2 VLT validation commands
The following commands are only applicable to the dual switch with VLT topology.
8.2.1 show vlt brief
This command is used to validate the VLT configuration status. The Role for one switch in the VLT pair is
Primary, and its peer switch (not shown) is assigned the Secondary role. The Inter-chassis link (ICL)
Link Status, Heart Beat Status and VLT Peer Status must all be Up. Ensure Peer-Routing is
Enabled.
S5048F-Leaf1A#show vlt brief
VLT Domain Brief
------------------
Domain ID: 127
Role: Primary
Role Priority: 32768
ICL Link Status: Up
HeartBeat Status: Up
VLT Peer Status: Up
Local Unit Id: 0
Version: 6(7)
Local System MAC address: d8:9e:f3:a7:26:20
Remote System MAC address: d8:9e:f3:bb:d6:20
Remote system version: 6(7)
Delay-Restore timer: 90 seconds
Delay-Restore Abort Threshold: 60 seconds
Peer-Routing : Enabled
Peer-Routing-Timeout timer: 0 seconds
Multicast peer-routing timeout: 150 seconds