Users Guide

Switch validation
36 Dell EMC Networking OS9 Switch Configuration Guide for VxRail 4.5
Note: The command output for the dual switch without VLT topology is shown below. In this example,
LAG 127 is the LACP port channel used as the switch interconnect.
S5048F-Leaf1A#show interfaces port-channel brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
A - Auto Port-channel
I - Internally Lagged
LAG Mode Status Uptime Ports
L 127 L2L3 up 00:04:11 Hu 1/53 (Up)
Hu 1/54 (Up)
8.1.3 show vlan
The show vlan command is used to view interfaces assigned to each VLAN and whether the interfaces are
untagged (U), tagged (T), or VLT (V).
S5048F-Leaf1A#show vlan
Codes: * - Default VLAN, G - GVRP VLANs, R - Remote Port Mirroring VLANs, P -
Primary, C - Community, I - Isolated
O - Openflow, Vx - Vxlan
Q: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
o - OpenFlow untagged, O - OpenFlow tagged
G - GVRP tagged, M - Vlan-stack
i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged
NUM Status Description Q Ports
* 1 Active U Po127(Hu 1/53,1/54)
1611 Active InBand_Mgmt V Po127(Hu 1/53,1/54)
U Tf 1/9,1/17-1/20
1612 Active vMotion V Po127(Hu 1/53,1/54)
T Tf 1/17-1/20
1613 Active vSAN V Po127(Hu 1/53,1/54)
T Tf 1/17-1/20
1614 Active VM_Network_A V Po127(Hu 1/53,1/54)
T Tf 1/17-1/20
1615 Active VM_Network_B V Po127(Hu 1/53,1/54)
T Tf 1/17-1/20