Configure switches
26 Dell EMC Networking OS9 Switch Configuration Guide for VxRail 4.5
7.2 Dual switch without VLT
This example uses a four-node VxRail cluster connected to a switch pair without VLT as shown below.
25GbE connections
100GbE LACP connections,
ports 1/53-54
Rack 1
S5048F-Leaf1A S5048F-Leaf1B
LACP
1/20 1/19 1/18 1/17 1/17 1/18 1/19 1/20
VxRail node 1
VxRail node 2
VxRail node 3
VxRail node 4
The jump box/DNS server, not shown,
is connected to port 1/9 on each
switch.
Four-node cluster connected to a switch pair without VLT
In this topology, an LACP port channel is used to connect the two switches.
The commands in the following sections are run to complete the configuration of both switches. The port
numbers used in the configuration commands correspond to those shown in Figure 13.
Note: The commands in the tables below should be entered in the order shown. All commands are provided
in the file attachments named S5048F-1A-no-vlt.txt and S5048F-1B-no-vlt.txt.
7.2.1 General settings
Configure the hostname, OOB management IP address and default gateway. Specify an NTP server
accessible by the switch. Enable LLDP for troubleshooting. Enable RSTP as a precaution against loops.
Configure S5048F-Leaf1A as the primary RSTP root bridge using the bridge-priority 0 command and
S5048F-Leaf1B as the secondary RSTP root bridge using the bridge-priority 4096 command.
General settings - dual switch without VLT
S5048F-Leaf1A
S5048F-Leaf1B
enable
configure terminal
hostname S5048F-Leaf1A
enable
configure terminal
hostname S5048F-Leaf1B