Deployment Guide
24 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS9
4.4.3 show vlt mismatch
Show VLT mismatch lists VLANs configured on a single switch in the VLT domain. The output shows the two
VLANs associated with Data 1 and Data 2 are listed.
S5048F-Leaf-1#sh vlt mismatch
Domain
------
Parameters Local Peer
---------- ----- ----
Vlan-config
------------
Vlan-ID Local Mode Peer Mode
--------- ------------ -----------
1634 L3 --
1635 -- L3
4.4.4 show vrrp brief
The output from the show vrrp brief command should be similar to that shown below. The priority (Pri column)
of the master router in the pair is 254, and the backup router (not shown) is assigned priority 1. Note that
some of the descriptions have been truncated to fit the document.
S5048F-Leaf1#show vrrp brief
Interface Group Pri Pre State Master addr Virtual addr(s) Description
--------------------------------------------------------------------------------
Vl 1630 IPv4 30 254 Y Master 172.16.30.251 172.16.30.254 IDRAC_MGMT_IP…
Vl 1631 IPv4 31 254 Y Master 172.16.31.251 172.16.31.253 ESXI_MGMT_IP
Vl 1633 IPv4 33 254 Y Master 172.16.33.251 172.16.33.253 SVM_MGMT_IP