Deployment Guide

18 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS9
enable
configure
hostname S5048F-Leaf1
protocol lldp
advertise management-tlv management-address system-description system-name
advertise interface-port-desc
interface ManagementEthernet 1/1
ip address 192.168.255.1/30
no shutdown
policy-map-input TrustDSCPin
trust diffserv
Next, the VLT interfaces between S5048F-Leaf1 and S5048F-Leaf2 are configured. In this configuration, add
interfaces hundredGigE 1/53-54 to static port channel 127 for the VLT interconnect. The backup destination is
the management IP address of the VLT peer switch, S5048F-Leaf2. Finally, VLT peer-routing is enabled
providing forwarding redundancy in the event of a switch failure.
Note: See Section 7.1 for Maximum Transmission Unit (MTU) guidelines used in this guide.
interface port-channel 127
description VLTi
mtu 9216
channel-member hundredGigE 1/53 - 1/54
no shutdown
interface range hundredGigE 1/53 - 1/54
description VLTi
mtu 9216
service-policy input TrustDSCPin
no shutdown
vlt domain 127
peer-link port-channel 127
back-up destination 192.168.255.2/30
unit-id 0
peer-routing
The downstream interfaces to the VxFlex Ready Nodes are configured in the next set of commands. The
downstream interface to the S3048-ON management switch is also configured.
interface twentygigabitethernet 1/1
description To R730xd-1
switchport
spanning-tree rstp edge-port
mtu 9216
service-policy input TrustDSCPin
no shutdown
interface twentygigabitethernet 1/3
description To R730xd-2