Failure Scenarios
The following sections describe some of the common fault conditions that can happen in a switch stack and how they are resolved.
Stack Member Fails
Problem: A unit that is not the stack master fails in an operational stack.
Resolution: If a stack member fails in a daisy chain topology, a split stack occurs. If a member unit fails in a ring topology, trac is re-routed
over existing stack links.
Dell#Feb 13 15:26:18: %STKUNIT4-M:CP %IPC-2-STATUS: target stack unit 2 not responding
Feb 13 15:26:19: %STKUNIT4-M:CP %CHMGR-2-STACKUNIT_DOWN: Major alarm: Stack unit 2 down - IPC
timeout
Feb 13 15:26:19: %STKUNIT4-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 2/1
Feb 13 15:26:19: %STKUNIT4-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Po 1
Feb 13 15:26:19: %STKUNIT4-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 2/0-11,20-23, Fo 2/
48,52,56,60,
Feb 13 15:26:19: %STKUNIT3-S:CP %IFMGR-1-DEL_PORT: Removed port: Te 2/0-11,20-23, Fo 2/
48,52,56,60,
Unplugged Stacking Cable
Problem: A stacking cable is unplugged from a member switch. The stack loses half of its bandwidth from the disconnected switch.
Resolution: Intra-stack trac is re-routed on another link using the redundant stacking port on the switch. A recalculation of control plane
and data plane connections is performed.
Master Switch Fails
Problem: The master switch fails due to a hardware fault, software crash, or power loss.
Resolution: A failover procedure begins:
1 Keep-alive messages from the master switch time-out after 60 seconds and the switch is removed from the stack.
2 The standby switch takes the master role. Data trac on the new master switch is uninterrupted. The control plane manages the
Protocol trac.
3 A member switch is elected as the new standby. Data trac on the new standby is uninterrupted. The control plane prepares for
operation in Warm Standby mode.
Stack-Link Flapping Error
Problem/Resolution: Stacked switches monitor their own stack ports and disable any stack port that aps ve times within 10 seconds. If
the stacking ports that ap are on the master or standby, KERN-2-INT error messages note the units.
Stacking