White Papers
• When you apply the FCoE map to a server-facing Ethernet port in ENode mode, ACLs are automatically congured to allow only FCoE
trac from servers that perform a successful FLOGI on the FC switch. All other trac on the VLAN is denied.
You can specify one or more upstream N ports in an FCoE map. The FCoE map also contains the VLAN ID of the dedicated VLAN used to
transmit FCoE trac between the SAN fabric and servers.
NPIV Proxy Gateway: Protocol Services
An S5000 NPG provides the following protocol services.
• Fibre Channel service to create N ports and log in to an upstream FC switch.
• FCoE service to perform:
• Virtualization of FC N ports on an NPG so that they appear as FCoE FCFs to downstream servers.
• NPIV service to perform the association and aggregation of FCoE servers to upstream F ports on core switches (through N ports
on the NPG). Conversion of server FLOGIs and FDISCs, which are received over S5000 ENode ports, are converted into FDISCs
addressed to the upstream F ports on core switches.
NPIV Proxy Gateway Functionality
An NPG provides the following functionality in a storage area network.
• FIP snooping bridge that provides security for FCoE trac using ACLs (refer to FCoE Transit chapter).
• FCoE gateway that provides FCoE-to-FC bridging. N-port virtualization using FCoE maps exposes upstream F ports as FCF ports to
downstream server-facing ENode ports on the NPG (refer FCoE Maps).
NPIV Proxy Gateway: Terms and Denitions
The following table describes the terms used in an NPG conguration on the S5000.
Table 63. S5000 NPIV Proxy Gateway: Terms and
Denitions
Term Description
FC port Fibre Channel port on an S5000 FC module that operates in
autosensing, 2–, 4–, or 8-Gigabit mode. On an NPIV proxy gateway,
an FC port can be used as a downlink for a server connection and
an uplink for a fabric connection.
F port Port mode of an FC port connected to an end node (N) port on an
S5000 NPIV proxy gateway.
N port Port mode of an S5000 FC port that connects to an F port on an
FC switch in a SAN fabric. On an S5000 NPIV proxy gateway, an N
port also functions as a proxy for multiple server CNA-port
connections.
ENode port Port mode of a server-facing S5000 Ethernet port that provides
access to FCF functionality on a fabric.
CNA port N-port functionality on an FCoE-enabled server port. A converged
network adapter (CNA) can use one or more Ethernet ports. CNAs
can encapsulate Fibre Channel frames in Ethernet for FCoE
transport and de-encapsulate Fibre Channel frames from FCoE to
native Fibre Channel.
NPIV Proxy Gateway 609