Enter 4 or 8 for the number of OpenFlow FP blocks.
4: Creates 242 entries for use by the OpenFlow controller (256 total entries
minus the 14 entries reserved for internal functionality)
8: Creates 498 entries for use by the OpenFlow controller (512 total entries
minus the 14 entries reserved for internal functionality)
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.2(0.2) Added support for the fcoe parameter on the S4810 and S4820T.
9.1.(0.0) Added support for OpenFlow on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Added the keywords fcoeacl and iscsioptacl on the S4810.
8.3.11.1 Introduced on the Z9000.
8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos.
8.2.1.0 Introduced on the S-Series.
7.8.1.0 Introduced on the C-Series.
Usage Information
For the new settings to take eect, save the new CAM settings to the startup-cong (write-mem or
copy run start) then reload the system.
The total amount of space allowed is 16 FP Blocks. System ow requires three blocks and these blocks
cannot be reallocated. The ipv4acl prole range is from 1 to 4.
When conguring space for IPv6 ACLs, the total number of Blocks must equal 13.
Ranges for the CAM proles are from 1 to 10, except for the ipv6acl prole which is from 0 to 10. The
ipv6acl allocation must be a factor of 2 (2, 4, 6, 8, 10).
If you enabled BMP, to perform a reload on the chassis to upgrade any conguration changes that have
changed the NVRAM content, use the reload conditional nvram-cfg-change command.