Users Guide
p-snooping max-sessions-per-enodemac
Congure the maximum number of FIP-snooping sessions supported on the switch for an ENode MAC address.
S5000
Syntax
fip-snooping max-sessions-per-enodemac max-value
To remove the congured number of supported sessions, use the no fip-snooping max—sessions-
per-enodemac command.
Parameters
max-value Enter the maximum number of FIP snooping sessions with an ENode that are
supported on the switch. The range is 1 to 64.
Defaults 32
Command Modes
• CONFIGURATION
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage Information The maximum number of supported FIP snooping sessions that you congure is displayed in the running
conguration (if it is not the default value) and in show fip-snooping config output.
If you congure a smaller number of supported sessions than was previously congured, all current FIP
snooping sessions continue and a warning message is displayed. If a greater number of sessions are active
with an ENode, additional sessions are not allowed as long as the total number is greater than the newly
congured limit.
When the maximum number of FIP snooping sessions for an ENode are already active on the switch, a log
message is recorded if the ENode tries to log in to initiate another session.
p-snooping port-mode fcf
Congure the port for bridge-to-FCF links.
Syntax
fip-snooping port-mode fcf
To disable the bridge-to-FCF link on a port, use the no fip-snooping port-mode fcf command.
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the Z9500 and S6000-ON.
FIP Snooping
609