Users Guide

Dell#show environment thermal-sensor
-- Thermal Sensor Readings (degree C) --
-- Unit 0 --
S0 S1 S2 S3 S4 S5 S6 S7
---------------------------------------------------------------
BASE BOARD 40 26 26 29 28 41 26 28
Module 0 30 31 22 19 23 20 - -
Module 1 28 29 21 - - - - -
Module 2 20 25 24 21 22 23 - -
Module 3 20 25 24 - - - - -
show inventory
Display the S-Series or Z-Series switch type, components (including media), and Dell Networking Operating System (OS), including
hardware identication numbers and congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member for which you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking Operating System version 8.3.11.4. Because stacking is not
supported, if you use this parameter, the output displays “Media not present or accessible” (refer to the
Usage Information
section).
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.4 Output expanded to include Piece Part ID (PPID) and eSR4 optics.
8.3.11.1 Introduced on the Z9000.
7.6.1.0 Introduced this version of the command for S-Series. S-Series output diers from E-Series.
Usage Information If there are no ber ports in the unit, just the header under show inventory media displays. If there are ber ports but no optics inserted, the output displays Media not
present or accessible.
Example (S6000)
Dell#show inventory
System Type : S6000
System Mode : 1.0
Software Version : 9-4(0-168)
136
Control and Monitoring