Users Guide

Passive — The passive system does not initiate a session. It only responds to
a request for session initialization from the active system.
The default is Active.
Defaults See Parameters
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2.0.0 Introduced on the Z9000, S4820T, and S4810.
Usage Information
This command provides the exibility to ne-tune the timer values based on individual interface needs when
you congure ipv6 ospf BFD in CONFIGURATION mode. Any timer values specied with this command
overrides timers set using the bfd all-neighbors command. Using the no form of this command does
not disable BFD if you congure BFD in CONFIGURATION mode.
To disable BFD on a specic interface while you congure BFD in CONFIGURATION mode, use the keyword
disable.
ipv6 ospf cost
Explicitly specify the cost of sending a packet on an interface.
Syntax
ipv6 ospf interface-cost
Parameters
interface-cost
Enter a unsigned integer value expressed as the link-state metric. The range is from
1 to 65535.
Defaults Default cost based on the bandwidth.
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.1.(0.0) Introduced on the S4810 and Z9000.
7.8.1.0 Added support for C-Series.
7.4.1.0 Introduced on the E-Series.
8.3.19.0 Introduced on the S4820T.
Open Shortest Path First (OSPFv2 and OSPFv3)