S5000-1#Feb 8 17:11:12: %STKUNIT2-M:CP %SYS-5-CONFIG_I: Configured from console
reload
System configuration has been modified. Save? [yes/no]: yes
!
Feb 8 17:11:14: %STKUNIT2-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config
in flash by default
Proceed with reload [confirm yes/no]: yes
Feb 8 17:11:17: %STKUNIT2-M:CP %CHMGR-5-RELOAD: User request to reload the
chassis
S5000-2(conf)#stack-unit 1 stack-group 2
S5000-2(conf)#Feb 8 17:10:00: %STKUNIT1-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports
Te 1/8 Te 1/9
Te 1/10 Te 1/11 have been configured as stacking ports. Please save and reload
for config to
take effect
S5000-2(conf)#stack-unit 1 stack-group 3
S5000-2(conf)#Feb 8 17:10:04: %STKUNIT1-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports
Te 1/12 Te 1/13
Te 1/14 Te 1/15 have been configured as stacking ports. Please save and reload
for config to
take effect
S5000-2(conf)#end
S5000-2#Feb 8 17:10:07: %STKUNIT1-M:CP %SYS-5-CONFIG_I: Configured from console
reload
System configuration has been modified. Save? [yes/no]: yes
!
Feb 8 17:10:10: %STKUNIT1-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config
in flash by default
Proceed with reload [confirm yes/no]: yes
Feb 8 17:11:47: %STKUNIT1-M:CP %CHMGR-5-RELOAD: User request to reload the
chassis
The following example shows viewing the two-switch stack configuration.
S5000-1#show system brief
Stack MAC : 5c:f9:dd:ef:0b:c0
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------
0 Member not present
1 Standby online S5000 S5000 9.1(1.0) 64
2 Management online S5000 S5000 9.1(1.0) 64
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
------------------------------------------------------