Dell EMC S5000 Installation Guide 9.6(0.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. NOTE: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide...........................................................................................................................5 Related Publications.............................................................................................................................................................. 5 2 Introduction................................................................................................................................ 6 Product Description...............
Replacing a Fan Module......................................................................................................................................................30 Installing the SFP+ and QSFP+ Optics.............................................................................................................................30 Splitting QSFP+ Ports to SFP+ Ports..............................................................................................................................
1 About this Guide This guide provides site preparation recommendations, and step-by-step procedures for rack mounting, installing and replacing pluggable modules, and connecting to a power source.
2 Introduction This document provides basic information about installing the S5000 switch. For information about how to configure and monitor switch features, refer to the Dell Networking OS Configuration Guide for the S5000 Switch, which is available on the Dell Support website at www.dell.com/support Topics: • Product Description Product Description This switch is part of Dell EMC S5000 Series of switches for Data Center Top of Rack (ToR) switches.
3 Unpacking the Switch The S5000 and its accessories are shipped in multiple boxes. Before unpacking the switch, inspect the container and immediately report any evidence of damage. Verify that you have received your ordered items. For example, if you order one S5000 switch, the following items are included. NOTE: If any item is missing or damaged, contact your Dell EMC representative or reseller for instructions. NOTE: Electrostatic discharge (ESD) damage can occur if components are mishandled.
Figure 1. S5000 I/O and Utility Panels 1. I/O panel 2. Utility panel 3. Four 40GbE QSFP+ ports (each port ALSO supports 4 × 10GbE mode) Hardware Installation Overview To install the S5000, follow these steps: 1. Attach the mounting brackets. 2. Install the S5000 chassis into a 4–post rack or cabinet. 3. Ground the rack. 4. Install the Ethernet and/or Fibre Channel modules (Fibre Channel module must be installed only in slot 0). 5. Install the power supplies. 6. Secure the power cables. 7.
4 Hardware Overview This section contains information about device characteristics and modular hardware configurations for the S5000. The S5000 has the following physical dimensions: • • • Height: 1.71 inches (43.5 mm) Width: 17.4 inches (441.9 mm) Depth: 28 inches (711.2 mm) The S5000 has a chassis design with 640Gbps switching bandwidth. The system also provides one DB9 RS-232 console port with YOST RJ-45 pinout and a dedicated Ethernet service port for out-of-band (OOB) management functions.
Utility Panel The Utility panel side of the platform contains the fan and power modules. Figure 3. S5000 Power Supplies and Fan Modules 1. Slot 0 (for PSU 0) 3. Slot 2 (for Fan Module 1) 5. Grab Handles 2. Slot 1 (for Fan Module 0) 4. Slot 3 (for PSU 1) Power Supplies The S5000 supports two hot-swappable PSUs. NOTE: The PSUs must be installed at the customer site.
The previous figure shows the fixed four 40GbE data ports (ports 48, 52, 56, and 60) and the four slots for pluggable modules on the S5000 I/ O panel. You can also use the 40GbE ports in 4 × 10GbE mode. The S5000 supports the following possible modules: • • 12-Port Ethernet Module (1G/10G speeds) (slot 0, 1, 2, or 3) 12-Port FC/Ethernet Universal Module (2G/4G/8G/10G speeds). The valid slot numbers are stack-unit numbers (from 0 to 11).
3. System status LED Table 1.
Label LED Color/Display Description • • • Green solid Green blinking • Link present and interface enabled (Ethernet module) Port has activity Module locator beacon LED • • Off Blue • • No activity Module beacon/locator Module status LED • • • Off Green solid Yellow • • • Module is not powered up Module is powered up Problem detected with module Table 3.
5 Site Preparations The S5000 is suitable for installation as part of a Common Bond Network (CBN). It can be installed in: • • • network telecommunication facilities data centers other locations where the National Electric Code (NEC) applies Topics: • • • Site Selection Cabinet Placement Storing Components Site Selection Dell EMC equipment is intended for installation in restricted access areas.
6 Installation Topics: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Before You Begin Installing in a Rack or Cabinet Attaching the Mounting Brackets Rack Mounting Safety Considerations Installing the S5000 Chassis into a 4-Post Rack or Cabinet Rack Grounding Important Points to Remember for Installing an Ethernet Module Installing an Ethernet Module Replacing an Ethernet Module Important Points to Remember for Installing a Fibre Channel Module Installing a Fibre Channel Module Replacing a Fi
• Switch is installed in an environment as free as possible from dust and foreign conductive material (such as metal flakes from construction activities). Cooling mechanisms, such as fans and blowers in the switch, can draw dust and other particles causing contaminant buildup inside the chassis, which can result in system malfunction. Installing in a Rack or Cabinet To install the S5000 system, Dell EMC recommends completing the installation procedures in the order presented here.
Rack Mounting Safety Considerations You may either place the switch on the rack shelf or mount the switch directly into a 19" wide, EIA-310-E- compliant rack. • • • • • • • Rack loading — Overloading or uneven loading of racks may result in shelf or rack failure, which may damage equipment and cause possible personal injury. Stabilize racks in a permanent location before loading begins. Mount the components beginning at the bottom of the rack, then work to the top. Do not exceed your rack load rating.
Rack Grounding When you prepare your equipment rack, ensure that the rack is earth ground. You must ground the equipment rack to the same ground point the power service uses in your area. The ground path must be permanent. Important Points to Remember for Installing an Ethernet Module • • Installing and swapping of Ethernet modules must be done BEFORE power up. If you need to install or replace a module, power down the system before you install or replace it.
Figure 11. Part name and Port number on the Ethernet Module Handle 1. Part Name 2. Port Number Installing an Ethernet Module 1. Use the grab handle on the Ethernet module to slide it into the switch module slot. 2. Connect any network interface cables to the attached module.
Figure 12. Installing an Ethernet Module 1. Release latch 2. Ethernet Module Replacing an Ethernet Module NOTE: S5000 does not support the hot swapping of an Ethernet pluggable module during switch operations. Instead, you must power down the switch before removing and replacing an expansion module. 1. Disconnect any network interface cables attached to the module. 2. Use the grab handle to slide the Ethernet module out of the switch module slot. 3.
Figure 13. Part name and Port number on the Fibre Channel Module Handle 1. Part Name 2. Port Number Installing a Fibre Channel Module 1. Use the grab handle on the Fibre Channel module to slide it into the switch module slot. 2. Connect any network interface cables to the attached module.
Figure 14. Installing a Fibre Channel Module 1. Release latch 2. Fibre Channel Module Replacing a Fibre-Channel Module NOTE: S5000 does not support the hot swapping of a Fibre-Channel pluggable module during switch operations. Instead, you must power down the switch before removing and replacing an expansion module. 1. Disconnect any network interface cables attached to the module. 2. Use the grab handle to slide the Fibre-Channel module out of the switch module slot. 3.
CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label indicates that hot air is expelled from the PSU and a blue label indicates that hot air is expelled from the I/O. Both power supplies must use the same airflow direction (I/O to Utility or Utility to I/O). The power supplies and fans must have the same color strap.
Figure 16. Connecting AC Power Supply Cords a. AC3 Prong NOTE: The system is powered-up as soon as you connect the power cord between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC system. Ensure that the socketoutlet is located/installed near the equipment and is easily accessible. 4. Repeat steps 1 through 3 above using the second PSU.
NOTE: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S5000 and its components. CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label indicates that hot air is expelled from the PSU and a blue label indicates that hot air is expelled from the I/O. Both fans must use the same airflow direction (I/O to Utility or Utility to I/O).
Installing a DC Power Supply 1. Remove the PSU from the electro-static bag. 2. Use the grab handle to slide the PSU into the switch PSU slot (install the PSU-exposed PCB edge connector first). The PSU slot is keyed so that the PSU can be fully inserted in only one way. When you correctly install the PSU, it snaps into place and is flush with the back of the switch. Figure 18. Installing a DC Power Supply a. Slot 0 (for DC PSU 0) b. Release latch 3.
Figure 19. Assembling the DC Input Power Wires 1. 3. 5. 7. DC power socket Captive screws (2) Wire (-48V) Grounding Wire 2. Rubber cap 4. DC power connector 6. Wire RTN NOTE: The system is powered-up as soon as the power cord is connected between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC or DC system.
Figure 20. Installing the Ferrite Bead for DC Power and Return Cables a. Ferrite Bead b. DC Power and Return Cables 3. Leave approximately 4 to 5 inches of the DC power and return cables end protruding from the ferrite. 4. Snap the ferrite bead shut. Securing Power Cables 1. Bend the system power cables, as shown in the following illustration, and attach to the cable clasp. Figure 21. Securing Power Cables 2.
NOTE: If a PSU fails, you must completely replace it. There are no field serviceable components in the PSU. 1. Disconnect the power cable from the PSU. 2. Use the grab handle to slide the PSU out of the switch PSU slot. 3. Use the grab handle on the replacement PSU to slide it into the switch PSU slot. 4. Attach the power cord to the replacement PSU. Important Points to Remember for Installing a Fan Module • • • • • • The Utility panel consists of four slots numbered from 0 to 3.
Figure 22. Installing a Fan Module a. Fan module 0/Slot 1 b. Release latch Replacing a Fan Module 1. Use the grab handle to slide the fan module out of the switch fan slot. 2. Use the grab handle on the replacement module to slide it into the switch fan slot. CAUTION: You must complete steps 1 and 2 within one minute or the system powers down. Installing the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four QSFP+ optical ports.
• • port - Enter the port number of the 40GbE port to be split. The range is 48 to 60. portmode quad - Configure a 40GbE port to operate in 4x10GbE mode. Example of splitting a QSFP+ port to SFP+ ports stack-unit 0 port 52 portmode quad Important Points to Remember • • • You cannot use split ports as a stack-link to stack an S5000 unit. The quad port must be in a default configuration before you can split it into four 10GbE SFP+ ports.
Figure 24. Stacking Topology Connecting Two S5000 Systems To provide backup connectivity and increased data transfer between the systems, Dell EMC recommends inserting an additional cable between the two units, in a second stacking port. You can use any of the SFP+ or QSFP+ ports for stacking, provided it is configured as a stacking port. CAUTION: The S5000 does not require special stacking cables. The cables used to connect 10GbE and 40GbE data ports are sufficient.
Connecting Three S5000 Systems To provide backup connectivity and increased data transfer between the systems, Dell EMC recommends inserting an additional cable between the two units, in a second stacking port. CAUTION: The S5000 does not require special stacking cables. The cables used to connect 10GbE and 40GbE data ports are sufficient. NOTE: The port numbers in the following procedure are used as examples only. 1. Insert one end of the first cable into stack port 60 of chassis 1 (bottom). 2.
Supplying Power and Powering Up the System Supply power to the S5000 system after the chassis is mounted in a rack or cabinet. NOTE: Installing and swapping of Fibre Channel or Ethernet modules must be done BEFORE power up. If you need to replace a module, power down the system before you replace it. If you replace a module when the system is powered up, the system does not recognize the module. Online insertion of modules can result in a catastrophic failure.
DC Power Connect the plug to each DC receptacle. Make sure that the power cord is secure and the polarity is correct. As soon as the cable is connected between the S5000 and the power source, the chassis is powered-up; there is no on/off switch. Hot-Swapping Units in a Stack You can add, remove, or swap S5000 units in an existing stack. The units in the stack and the new units can be already powered up or powered down. All units in a stack must run the same version of the operating system.
7 Technical Specifications NOTE: Operate the product at an ambient temperature not higher than 40°C. CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to the manufacturer's instructions. Table 5. Chassis Physical Design Parameter Specifications Height 1.71 inches (43.5 mm) Width 17.
8 Agency Compliance USA Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, under Part 15 of the FCC rules. These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy.
Germany Japan: VCCI Compliance for Class A Equipment NOTE: Use the AC power cords with Dell EMC equipment only. Do not use Dell EMC AC power cords with any unauthorized hardware. This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Safety Standards and Compliance Agency Certifications • • • • • • • • CUS UL 60950-1, Second Edition CSA 60950-1-03, Second Edition EN 60950-1, Second Edition EN 60825-1, First Edition EN 60825-1 Safety of Laser Products — Part 1: Equipment Classification Requirements and User’s Guide EN 60825-2 Safety of Laser Products — Part 2: Safety of Optical Fibre Communication Systems FDA Regulation 21CFR 1040.10 and 1040.
must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, Specifications | 47 recycling and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE.
9 Technical Support Topics: • • • • The iSupport Website Accessing iSupport Services Requesting a Hardware Replacement Contacting Technical Support The iSupport Website iSupport provides a range of documents and tools to assist you with effectively using Dell EMC equipment and mitigating the impact of network outages. Through iSupport you can obtain technical information regarding Dell EMC products, access to software upgrades and patches, and open and manage your Tech Support cases.
Information to Submit When Opening a Support Case • • • • • • • • • • • Your name, company name, phone number, and E-mail address Preferred method of contact Model number Software version number Symptom description Screen shots showing the symptom, including any error messages. This can include: Output from the show tech-support command (This report is very long so set the storage buffer in your terminal program to high.