Deployment Guide
Table Of Contents
- Getting Started Guide
- Introduction
- Hardware Overview
- Installation
- Installing the Rack or Cabinet
- Attaching the Mounting Brackets
- Rack Mounting Safety Considerations
- Installing the S5000 Chassis into a 4-Post Rack or Cabinet
- Rack Grounding
- Important Points to Remember for Installing an Ethernet Module
- Installing an Ethernet Module
- Important Points to Remember for Installing a Unified Port Module
- Installing a Unified Port Module
- Important Points to Remember for Installing an AC Power Supply
- Installing an AC Power Supply
- Assembling and Connecting the Safety Ground Wire for DC Power Supply
- Important Points to Remember for Installing a DC Power Supply
- Installing a DC Power Supply
- Installing the Ferrite Bead for DC Power and Return Cables
- Securing Power Cables
- Important Points to Remember for Installing a Fan Module
- Installing a Fan Module
- Installing the SFP+ and QSFP+ Optics
- Splitting QSFP+ Ports to SFP+ Ports
- Supplying Power and Powering Up the System
- Performing the Initial Configuration
- Software Configuration Overview
- Accessing the RJ-45/RS-232 Console Port
- Accessing the RJ-45 Console Port with a DB-9 Adapter
- Accessing the USB-B Console Port
- Enter the Initial Configuration Information
- Configuring the Enable Password
- Configuring a Host Name
- Navigate CLI modes
- Default Configuration
- Configuring Layer 2 (Data Link) Mode
- Accessing the System Remotely
- Configuring the Management Port IP Address
- Configuring a Management Route
- Configuring a Username and Password
- Creating a Port-based VLAN
- Assigning Interfaces to a VLAN
- Assigning an IP Address to a VLAN
- Connecting the S5000 to the Network
- Technical Specifications

5. Four 40GbE QSFP+ ports (each port ALSO
supports 4 × 10GbE mode)
NOTE: The LED displays for the system status are on both sides of the chassis. The fan and power
status LEDs are on the Utility panel.
Utility Panel
The Utility panel side of the platform contains the fan and power modules.
Figure 3. S5000 Power Supplies and Fan Modules
1. Slot 0 (for PSU 0) 2. Slot 1 (for Fan Module 0)
3. Slot 2 (for Fan Module 1) 4. Slot 3 (for PSU 1)
5. Grab Handles
Power Supplies
The S5000 supports two hot-swappable PSUs.
NOTE: The PSUs must be installed at the customer site.
The S5000 has SKUs that support the following configurations:
• AC PSU with fan airflow from I/O to Utility
• AC-R PSU with fan airflow from Utility to I/O
• DC PSU with fan airflow from I/O to Utility
• DC-R PSU with fan airflow from Utility to I/O
PSUs are field replaceable. To ensure power redundancy and adequate cooling, install two power
supplies in the switch. When running with full redundancy (two PSUs installed and running), you can
remove and replace one PSU while the other PSU is running without disrupting traffic.
Fans
The S5000 supports two fan trays with airflow directions from I/O to Utility or Utility to I/O.
Do not mix I/O to Utility and Utility to I/O airflows in a single S5000 chassis. All fans and PSUs in a
configuration must be in the same airflow direction. If you create a mixed airflow configuration, the
software notifies you of the invalid configuration.
8