Deployment Guide
Table Of Contents
- Getting Started Guide
- Introduction
- Hardware Overview
- Installation
- Installing the Rack or Cabinet
- Attaching the Mounting Brackets
- Rack Mounting Safety Considerations
- Installing the S5000 Chassis into a 4-Post Rack or Cabinet
- Rack Grounding
- Important Points to Remember for Installing an Ethernet Module
- Installing an Ethernet Module
- Important Points to Remember for Installing a Unified Port Module
- Installing a Unified Port Module
- Important Points to Remember for Installing an AC Power Supply
- Installing an AC Power Supply
- Assembling and Connecting the Safety Ground Wire for DC Power Supply
- Important Points to Remember for Installing a DC Power Supply
- Installing a DC Power Supply
- Installing the Ferrite Bead for DC Power and Return Cables
- Securing Power Cables
- Important Points to Remember for Installing a Fan Module
- Installing a Fan Module
- Installing the SFP+ and QSFP+ Optics
- Splitting QSFP+ Ports to SFP+ Ports
- Supplying Power and Powering Up the System
- Performing the Initial Configuration
- Software Configuration Overview
- Accessing the RJ-45/RS-232 Console Port
- Accessing the RJ-45 Console Port with a DB-9 Adapter
- Accessing the USB-B Console Port
- Enter the Initial Configuration Information
- Configuring the Enable Password
- Configuring a Host Name
- Navigate CLI modes
- Default Configuration
- Configuring Layer 2 (Data Link) Mode
- Accessing the System Remotely
- Configuring the Management Port IP Address
- Configuring a Management Route
- Configuring a Username and Password
- Creating a Port-based VLAN
- Assigning Interfaces to a VLAN
- Assigning an IP Address to a VLAN
- Connecting the S5000 to the Network
- Technical Specifications

c. 8 data bits
d. 1 stop bit
e. No flow control
Figure 23. RS-232/RJ-45 Console Port
Accessing the RJ-45 Console Port with a DB-9 Adapter
You can connect to the console using an RJ-45 to RJ-45 rollover cable and an RJ-45 to DB-9 female
DTE adapter to a terminal server (for example, a PC).
The pin assignments between the console and a DTE terminal server are as follows:
Table 8. Pin Assignments Between the Console and a DTE Terminal Server
S5000 Console
Port
RJ-45 to RJ-45
Rollover Cable
RJ-45 to RJ-45
Rollover Cable
RJ-45 to DB-9
Adapter
Terminal Server
Device
Signal RJ-45 Pinout RJ-45 Pinout DB-9 Pin Signal
RTS 1 8 8 CTS
NC 2 7 6 DSR
TxD 3 6 2 RxD
GND 4 5 5 GND
GND 5 4 5 GND
RxD 6 3 3 TxD
NC 7 2 4 DTR
CTS 8 1 7 RTS
Accessing the USB-B Console Port
The terminal settings are the same for the USB-B port and the console port:
• 9600 baud rate
• No parity
34