Administrator Guide
Example of the show fcoe-map Command
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State Oper-State
fid_1003 1003 1003 0efc03 128 ACTIVE UP
fid_1004 1004 1 004 0efc04 128 ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/0
Te 0/14 Te 0/16
The following lists the show fcoe-map command example eld descriptions.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage trac between servers and a fabric over the NPG. The
congured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. (This setting is not user-congurable.)
FC-MAP FCoE MAC-address prex value — The unique 24-bit MAC address prex that identies a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority a server uses to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are valid:
• Active (all mandatory FCoE and FC parameters are correctly congured)
• Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly congured)
Oper-State Operational status of link to the fabric:
• up (link is up and transmitting FC trac)
• down (link is down and not transmitting FC trac),
• link-wait (link is up and waiting for FLOGI to complete on peer FC port)
• removed (port has been shut down)
Members Ethernet and FC ports that are members of the dedicated FCoE VLAN that carries storage trac to the specied
fabric.
Example of the show qos-dcb-map Command
Dell# show qos dcb-map dcbmap2
State :Complete
PfcMode:ON
--------------------
PG:0 TSA:ETS BW:50 PFC:OFF
Priorities:0 1 2 4 5 6 7
NPIV Proxy Gateway
611