Administrator Guide
iscsiOptAcl : 0
ipv4pbr : 0
vrfv4Acl : 0
Openflow : 0
fedgovacl : 0
nlbclusteracl: 0
st-sjc-s5000-29#
Enabling the FCoE Transit Feature
The following sections describe how to enable FCoE transit.
NOTE: FCoE transit is disabled by default. To enable this feature, you must follow the Conguring FIP
Snooping.
As soon as you enable the FCoE transit feature on a switch-bridge, existing VLAN-specic and FIP snooping congurations are applied.
The FCoE database is populated when the switch connects to a converged network adapter (CNA) or FCF port and compatible DCB
congurations are synchronized. By default, all FCoE and FIP frames are dropped unless specically permitted by existing FIP snooping-
generated ACLs. You can recongure any of the FIP snooping settings.
If you disable FCoE transit, FIP and FCoE trac are handled as normal Ethernet frames and no FIP snooping ACLs are generated. The
VLAN-specic and FIP snooping conguration is disabled and stored until you re-enable FCoE transit and the congurations are re-applied.
Enable FIP Snooping on VLANs
You can enable FIP snooping globally on a switch on all VLANs or on a specied VLAN.
When you enable FIP snooping on VLANs:
• FIP frames are allowed to pass through the switch on the enabled VLANs and are processed to generate FIP snooping ACLs.
• FCoE trac is allowed on VLANs only after a successful virtual-link initialization (fabric login FLOGI) between an ENode and an FCF. All
other FCoE trac is dropped.
• You must congure at least one interface for FCF (FIP snooping bridge-bridge) mode on a FIP snooping-enabled VLAN.
• On an S5000 NPIV proxy gateway:
• A maximum of 12 VLANs are supported for FIP snooping.
• The maximum number of FCFs supported on a FIP snooping-enabled VLAN is 12.
• In NPIV mode, FIP Snooping does not work when the default VLAN is other then VLAN1.
• On an S5000 switch not congured as an NPIV proxy gateway:
• A maximum of eight VLANs are supported for FIP snooping.
• The maximum number of FCFs supported on a FIP snooping-enabled VLAN is 12.
NOTE
: When you enable FCoE transit, FIP solicitation responses from an FCF may be forwarded on an FCoE VLAN to multiple
ENodes.
Congure the FC-MAP Value
You can globally congure the FC-MAP on all or individual FCoE VLANs to authorize FCoE trac.
to check the FC-MAP value for the MAC address assigned to ENodes in incoming FCoE frames, use the congured FC-MAP value. If the
FC-MAP value does not match, FCoE frames are dropped. A session between an ENode and an FCF is established by the switch-bridge
only when the FC-MAP value on the FCF matches the FC-MAP value on the FIP snooping bridge.
322