• upgrade (S-Series management unit and Z-Series) – upgrades the bootflash
image or system image of the S-Series management unit.
show system stack-unit stack-group
Display the stacking group port information for the specified stack-unit.
Syntax
show system stack-unit stack-unit stack-group
Defaults none
Command
Modes
GLOBAL
Command
History
Version
8.3.10.2
Introduced on the S4810.
Example
Dell#show system stack-unit 0 stack-group
Stack Group Ports
------------------------------
0 0/0, 1, 2, 3
1 0/4, 5, 6, 7
2 0/8, 9, 10, 11
3 0/12, 13, 14, 15
4 0/16, 17, 18, 19
...
13 0/48
14 0/52
15 0/56
16 0/60
stack-unit priority
Configure the ability of a switch to become the management unit of a stack.
Syntax
stack-unit stack-number priority 1-14
Parameters
stack-number Enter the stack member unit identifier.
1–14 This preference parameter allows you to specify the
management priority of one backup switch over another,
with 0 the lowest priority and 14 the highest. The switch with
the highest priority value is chosen to become the
management unit if the active management unit fails or on
the next reload.
Defaults 0
Stacking Commands
1909