Reference Guide

Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.11.1 Introduced on the Z9000.
Version 7.7.1.0 Introduced on the S-Series.
Usage
Information
To modify your results, use the show redundancy [pipe] command, as follows:
except — show only text that doesn not match a pattern.
find — search for the first occurrence of a pattern.
grep — show only text that matches a pattern.
no-more — do not paginate the output.
save — save the output to a file.
Example
Dell#show redundancy
Dell#show redundancy
-- SSeries Redundancy Configuration --
------------------------------------------------
Auto reboot : Enabled
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 7.7.1.0
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 1
Stack-unit SW Version: 7.7.1.0
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Enabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: succeeded Jul 11 2012 09:42:35
Start-up Config: succeeded Jul 11 2012 09:42:35
Runtime Event Log: succeeded Jul 11 2012 09:42:35
1906
Stacking Commands