Reference Guide

Term heading Description heading
PFC PFC setting for the priority group: On (enabled) or Off.
Priorities 802.1p priorities configured in the priority group.
Dell# show npiv devices brief
Total NPIV Devices = 2
--------------------------------------------------------------------------------
--
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf Fabric-Map LoginMethod
Status
--------------------------------------------------------------------------------
---
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5 fid_1003 FLOGI
LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0 fid_1003 FDISC
LOGGED_IN
The following lists the show npiv devices brief command example field descriptions.
Field Description
Total NPIV Devices Number of downstream ENodes connected to a fabric over the NPIV proxy
gateway.
ENode-Intf Ethernet interface (slot/port) to which a server CNA is connected.
ENode-WWPN Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE traffic to and from the
fabric.
Fabric-Intf Fabric-facing Fibre Channel port (slot/port) on which FC traffic is transmitted to the
specified fabric.
Fabric-Map Name of the FCoE map containing the FCoE/FC configuration parameters for the
server CNA-fabric connection.
Login Method Method the server CNA uses to log in to the fabric; for example:
FLOGI - ENode logged in using a fabric login (FLOGI).
FDISC - ENode logged in using a fabric discovery (FDISC).
Status Operational status of the link between a server CNA port and a SAN fabric: Logged
In — Server has logged in to the fabric and is able to transmit FCoE traffic.
Example of the show npiv devices Command
Dell# show npiv devices
ENode[0] :
ENode MAC : 00:10:18:f1:94:21
ENode Intf : Te 0/12
FCF MAC : 5c:f9:dd:ef:10:c8
Fabric Intf : Fc 0/5
FCoE Vlan : 1003
Fabric Map : fid_1003
ENode WWPN : 20:01:00:10:18:f1:94:20
ENode WWNN : 20:00:00:10:18:f1:94:21
FCoE MAC : 0e:fc:03:01:02:01
FC-ID : 01:02:01
LoginMethod : FLOGI
652
NPIV Proxy Gateway