Reference Guide

converged network adapter (CNA) or FCF port and compatible DCB configurations are synchronized. By
default, all FCoE and FIP frames are dropped unless specifically permitted by existing FIP snooping-
generated ACLs. You can reconfigure any of the FIP snooping settings.
If you disable FCoE transit, FIP and FCoE traffic are handled as normal Ethernet frames and no FIP
snooping ACLs are generated. The VLAN-specific and FIP snooping configuration is disabled and stored
until you re-enable FCoE transit and the configurations are re-applied.
NOTE: When you configure the S5000 switch as an NPIV proxy gateway and enable Fibre Channel
capability (the feature fc command), FIP snooping is automatically enabled on all VLANs on the
switch using the default FIP snooping settings.
FIP Snooping Prerequisites
Before you enable FCoE transit and configure FIP snooping on a switch, ensure that certain conditions
are met.
A FIP snooping bridge requires data center bridging exchange protocol (DCBx) and priority-based flow
control (PFC) to be enabled on the switch for lossless Ethernet connections (refer to the Data Center
Bridging (DCB)chapter). Dell Networking recommends also enabling enhanced transmission selection
(ETS); however, ETS is recommended but not required.
If you enable DCBx and PFC mode is on (PFC is operationally up) in a port configuration, FIP snooping is
operational on the port. If the PFC parameters in a DCBx exchange with a peer are not synchronized, FIP
and FCoE frames are dropped on the port after you enable the FIP snooping feature.
For VLAN membership, you must:
create the VLANs on the switch which handles FCoE traffic (use the interface vlan command).
configure each FIP snooping port to operate in Hybrid mode so that it accepts both tagged and
untagged VLAN frames (use the portmode hybrid command).
configure tagged VLAN membership on each FIP snooping port that sends and receives FCoE traffic
and has links with an FCF, ENode server, or another FIP snooping bridge (use the tagged port-type
slot/port
command).
The default VLAN membership of the port must continue to operate with untagged frames. FIP snooping
is not supported on a port that is configured for nondefault untagged VLAN membership.
Important Points to Remember
Enable DCBx on the switch before enabling the FIP Snooping feature.
To enable the feature on the switch, configure FIP Snooping.
To allow FIP frames to pass through the switch on all VLANs, enable FIP snooping globally on a
switch.
A switch can support a maximum eight VLANs. Configure at least one FCF/bridge-to-bridge port
mode interface for any FIP snooping-enabled VLAN.
You can configure multiple FCF-trusted interfaces in a VLAN.
When you disable FIP snooping:
ACLs are not installed, FIP and FCoE traffic is not blocked, and FIP packets are not processed.
The existing per-VLAN and FIP snooping configuration is stored. The configuration is re-applied
the next time you enable the FIP snooping feature.
356
FCoE Transit