Users Guide

Field Description
Fibre Channel ports — up (link is up and transmitting FC traffic) or down (link is
down and not transmitting FC traffic), link-wait (link is up and waiting for FLOGI to
complete on peer SW port), or removed (port has been shut down).
Speed Transmission speed (in Megabits per second) of Ethernet and FC iports, including auto-
negotiated speed (Auto).
Duplex Data transmission mode:
Full (allows communication in both directions at the same time)
Half (allows communication in both directions but not at the same time)
Auto (auto-negotiated transmission).
VLAN VLAN IDs of the VLANs in which the port is a member.
Example of the show fcoe-map Command
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State Oper-State
fid_1003 1003 1003 0efc03 128 ACTIVE UP
fid_1004 1004 1 004 0efc04 128 ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/0
Te 0/14 Te 0/16
The following lists the show fcoe-map command example field descriptions.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC traffic is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage traffic between servers and a fabric
over the NPG. The configured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE traffic uses VLAN priority 3. (This setting is not user-configurable.)
FC-MAP FCoE MAC-address prefix value — The unique 24-bit MAC address prefix that identifies
a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority a server uses to select an upstream FCoE forwarder.
Config-State Indicates whether the configured FCoE and FC parameters in the FCoE map are valid:
NPIV Proxy Gateway 714