Users Guide

Maximum unique members allowed in an alias : 2,000
Maximum NPIV devices supported per physical port: 64
Topics:
Configuring Switch Mode to Fabric Services
Name Server
Link State Database
Zoning
Configuring Switch Mode to Fabric
Services
To configure switch mode to Fabric services, use the following commands.
1 Configure Switch mode to Fabric Services.
CONFIGURATION mode
fc switch-mode fabric-services
2 Configure the SAN fabric to which the FC port connects by entering the name of the FCoE map applied
to the interface.
INTERFACE mode
fcoe-map <fcoe-map-name> {tengigabitEthernet slot/port | fortygigabitEthernet
slot/port}
The FCoE map contains FCoE and FC parameter settings (refer to FCoE Maps). Manually apply the
fcoe-map default_full_fabric to any Ethernet ports used for FCoE.
3 Configure the association between the dedicated VLAN used to carry FCoE traffic between servers and a
SAN, and the fabric where the desired storage arrays are installed.
FCOE MAP mode
fabric-id fabric-num vlan vlan-id
4 Configure the FCoE mapped address prefix (FC-MAP) value which is used to identify FCoE traffic
transmitted on the FCoE VLAN for the specified fabric.
FCOE MAP mode
fc-map fc-map-value
Fabric Services 377