Users Guide
Please make sure that stacking/fanout not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline
command is
issued.
Proceed with Offline [confirm yes/no]:
5w6d12h: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - stack unit
offline
5w6d12h: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 2/1-48
Dell#5w6d12h: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Te 2/1-48
The following is an example of verifying the offline/online status of a stack unit.
Dell#show system brief | no-more
Stack MAC : 5c:f9:dd:ee:ff:c0
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------
0 Management online S5000 S5000 9-0-1-0 64
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
-------------------------------------------------------
0 0 online S5000-MOD-12XETH10-F 12
0 1 not present No Module 0
0 2 online S5000-MOD-12XETH10-F 12
0 3 not present No Module 0
-- Power Supplies --
Unit Bay Status Type FanStatus
-------------------------------------------------------
0 0 up DC up
0 1 up DC up
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2 Speed Fan3 Speed
---------------------------------------------------------------
0 0 absent or down
0 1 up up 4800 up 4800 up 4800 up 4800
0 2 up up 4800 up 4800 up 4800 up 4800
0 3 absent or down
Dell#
As shown in the following two examples, log messages differ somewhat when diagnostics are done on a
standalone unit and on a stack member.
S5000 Debugging and Diagnostics 1233