Reference Guide
interval time-
in-minutes
Enter the keyword interval followed by the frequency in
minutes of the CAM audit. Range: 5 to 1440 minutes (24
hours). Default: 60 minutes.
Defaults Disabled
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
Enables periodic audits of the software and hardware copies of the IPv4 and IPv6
forwarding tables.
clear alarms
Clear alarms on the system.
S5000
Syntax
clear alarms
Command
Modes
EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
This command clears alarms that are no longer active. If an alarm situation is still
active, it is seen in the system output.
clear command history
Clear the command history log.
S5000
Syntax
clear command history
Command
Modes
EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Control and Monitoring