Reference Guide
Command
Modes
• EXEC
• EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Example
Dell# show iscsi session
Session 0:
------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0e70c2002-10a0018426a48c94-iom010
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000
Session 1:
---------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0f60c2002-0360018428d48c94-iom011
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000.
Related
Commands
• show iscsi – displays the currently configured iSCSI settings.
• show iscsi session detailed – displays detailed information about active iSCSI
sessions on the switch.
• show run iscsi – shows run iscsi.
show iscsi session detailed
Display detailed information on active iSCSI sessions on the switch.
S5000
Syntax
show iscsi session detailed [session isid]
Parameters
isid Enter the session’s iSCSi ID to display detailed information
about the specified iSCSi session.
Command
Modes
• EXEC
• EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Example
Dell# show iscsi session detailed
Session 0 :
---------------------------------------------------
Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1
Initiator:iqn.2010-11.com.ixia.ixload:initiator-iscsi-2c
804