Reference Guide
Command
History
Version 9.1(1.0) Introduced on the S5000.
Example
Dell#show fc route
Domain Id 2
=============================================================
Source FCF-Bridge Destination
=============================================================
Te 0/18 5c:f9:dd:ef:1e:03 Fc 0/11
Te 0/19 5c:f9:dd:ef:1e:04 Fc 0/11
=============================================================
Dell#
show fc switch
Display the switch configuration for Fibre Channel capability.
S5000
Syntax
show fc switch
Parameters None
Command
Modes
• EXEC
• EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The following table describes the show fc switch output shown in the following
example.
Switch Mode Fibre Channel mode of operation of an S5000 switch.
Default: NPG (configured as an NPIV proxy gateway).
Switch WWN Factory-assigned worldwide node (WWN) name of the
S5000. The S5000 WWN name is not user-configurable.
Example
Dell# show fc switch
Switch Mode : Fabric-Services
Switch WWN : 10:00:5c:f9:dd:ef:24:40
Dell#
Related
Commands
fc switch-mode fabric-services — changes the switch mode from NPIV Gateway
(NPG) mode to fabric-services mode.
interface fibrechannel — configures a Fibre Channel interface on the switch.
588
Fabric Services Commands