Reference Guide

Parameters
zoneset_name Enter the zoneset name.
Command
Modes
CONFIGURATION
Command
History
Version 9.1(1.0) Introduced on the S5000.
Example
Dell(conf)# fc zoneset zs1
Dell(conf-fc-zoneset-zs1)#
Related
Commands
show fc zoneset — displays the configured and active zoneset.
show fcoe-map — displays the fabric parameters.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs
and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.
S5000
Syntax
fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults None
Command
Modes
CONFIGURATION
INTERFACE
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an S5000 NPIV
proxy gateway so that they appear to downstream server CNA ports as FCoE
forwarder (FCF) ports on an FCoE network. When applied to FC and Ethernet ports
on an NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-
FC bridge between an FC SAN and an FCoE network by providing FCoE-enabled
servers and switches with the necessary parameters to log in to a SAN fabric.
On an S5000 NPIV proxy gateway, an FCoE map is applied on fabric-facing FC
ports and server-facing Ethernet ports. Use the fcoe-map command to apply an
FCoE map on an Ethernet port. Use the fabric command to apply an FCoE map
on an FC port.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN used
for storage traffic, the destination SAN fabric (FC-MAP value), FCF priority used by a
server, and the FIP keepalive (FKA) advertisement timeout.