Reference Guide
stack-unit unit-
number
(OPTIONAL) Enter the stack-unit keyword followed by the
unit number. The range is 0 to 11.
Command
Modes
• EXEC
• EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
In the Example, the delta column displays changes since the last screen refresh.
The following are the monitor command menu options.
systest-3 Displays the host name assigned to the system.
monitor time Displays the amount of time since the monitor interface
command was entered.
time Displays the amount of time the chassis is up (since last
reboot).
m Change the view from a single interface to all interfaces on
the stack-unit or visa-versa.
c Refresh the view.
b Change the counters displayed from Packets on the
interface to Bytes.
r Change the [delta] column from change in the number of
packets/bytes in the last interval to rate per second.
l Change the view to the next interface on the stack-unit.
a Change the view to the previous interface on the stack-unit.
T Increase the screen refresh rate.
t Decrease the screen refresh rate.
q Return to the CLI prompt.
Example (single
interface)
Dell# monitor interface te 0/1
systest-3 Monitor time: 00:00:06 Refresh Intvl.: 2s Time:
03:26:26
Interface: Te 0/1, Enabled, Link is Up, Linespeed is 1000 Mbit
Traffic statistics: Current Rate Delta
Input bytes: 9069828 43 Bps 86
Output bytes: 606915800 43 Bps 86
Input packets: 54001 0 pps 1
Output packets: 9401589 0 pps 1
64B packets: 67 0 pps 0
Over 64B packets: 49166 0 pps 1
Over 127B packets: 350 0 pps 0
Over 255B packets: 1351 0 pps 0
Over 511B packets: 286 0 pps 0
532