Reference Guide

Parameters
seconds (OPTIONAL) Enter the number of seconds between keepalive
packets. The range is 0 to 23767. The default is 10 seconds.
Defaults Enabled.
Command
Modes
INTERFACE
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
When you configure keepalive, the system sends a self-addressed packet out of
the configured interface to verify that the far end of a WAN link is up. When you
configure no keepalive, the system does not send keepalive packets and so the
local end of a WAN link remains up even if the remote end is down.
monitor interface
Monitor counters on a single interface or all interfaces on a stack-unit. The screen is refreshed every five
seconds and the CLI prompt disappears.
S5000
Syntax
monitor interface [type slot/port | stack-unit unit-number]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
interfacetype
slot/port
(OPTIONAL) Enter the interface keyword followed by the
interface type and slot/port or number information. Valid slot
numbers are 0-11. The valid port numbers for each interface
type are listed below.
For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet followed by slot/port numbers.
The port range is 0 to 63.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by slot/port numbers. The ports are
48, 52, 56, and 60.
For the management port, enter the keyword
managementethernet followed by the slot (0-1) and the
port (0).
For a Management interface, enter the keyword
managementethernet followed by slot/port numbers.
The port is 0.
For a Port Channel interface, enter the keywords port-
channel followed by a number from 1 to 128.
For a VLAN interface, enter the keyword vlan followed
by a VLAN id number from 1 to 4094.
Interfaces
531