Reference Guide

Field Description
The status of auto booting the stack-unit (the
redundancy disable-auto-reboot command)
The parameter for auto failover limit control (the
redundancy auto-failover-limit command)
Stack-unit
Failover Record
Displays the following information:
Stack-unit failover counter (to reset the counter, use the
redundancy reset-counter command)
The time and date of the last stack-unit failover
The reason for the last stack-unit failover
Last Data Sync
Record
Displays the data sync information and the timestamp for
the data sync:
Stack-unit Config is configured stack-units and their
interfaces.
Start-up Config is the contents of the startup-config file.
Runtime Event Log is the contents of the Event log.
Running Config is the current running-config.
ACL Mgr
LACP
STP
SPAN
This field only appears when you enter the command from
the management stack-unit.
Example
Dell#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: DIABLO-SYS-8-3-18-264
Link to Peer: Down
Peer Stack-unit: not present
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Disabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
High Availability (HA)
493