Reference Guide
Usage
Information
• Join Timer—Join messages announce the willingness to register some
attributes with other participants. For reliability, each GARP application entity
sends a Join message twice and uses a join timer to set the sending interval.
• Leave Timer—Leave announces the willingness to de-register with other
participants. Together with Join, Leave messages help GARP participants
complete attribute reregistration and de-registration. The leave timer starts after
receipt of a leave message sent for de-registering some attribute information. If
a
Join message is not received before the Leave time expires, the GARP
application entity removes the attribute information as requested.
• Leave All Timer—The Leave All timer starts when a GARP application entity
starts. When this timer expires, the entity sends a Leave-all message so that
other entities can reregister their attribute information. Then the
Leave-all
time begins again.
Related
Commands
show garp timers – displays the current GARP times.
gvrp enable
Enable GVRP on physical interfaces and LAGs.
S5000
Syntax
gvrp enable
To disable GVRP on the interface, use the no gvrp enable command.
Defaults Disabled.
Command
Modes
CONFIGURATION-INTERFACE
Command
History
Version 9.0(1.3) Introduced on the S5000.
Related
Commands
disable – globally disables GVRP.
gvrp registration
Configure the GVRP register type.
S5000
Syntax
gvrp registration {fixed | normal | forbidden}
To return to the default, use the gvrp register normal command.
GARP VLAN Registration (GVRP)
483