host ip-address Enter the keyword host and then enter the IP address to
specify a host IP address or hostname.
operator (OPTIONAL) Enter one of the following logical operands:
eq = equal to
neq = not equal to
gt = greater than
lt = less than
range = inclusive range of ports (you must specify two
ports for the port parameter.)
port port (OPTIONAL) Enter the application layer port number. Enter
two port numbers if you are using the range logical operand.
The range is from 0 to 65535.
The following list includes some common TCP port
numbers:
23 = Telnet
20 and 21 = FTP
25 = SMTP
169 = SNMP
destination Enter the IP address of the network or host to which the
packets are sent.
message-type (OPTIONAL) Enter an ICMP message type, either with the
type (and code, if necessary) numbers or with the name of
the message type. The range is from 0 to 255 for ICMP type
and 0 to 255 for ICMP code.
count (OPTIONAL) Enter the keyword count to count packets the
filter processes.
byte (OPTIONAL) Enter the keyword byte to count bytes the filter
processes.
dscp (OPTIONAL) Enter the keyword dcsp to match to the IP
DCSCP values.
order (OPTIONAL) Enter the keyword order to specify the QoS
order for the ACL entry. The range is from 0 to 254 (where 0
is the highest priority and 254 is the lowest; lower order
numbers have a higher priority). If you do not use the
keyword order, the ACLs have the lowest order by default
(255).
monitor (OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
214
Access Control Lists (ACL)