Reference Guide

offline stack-unit
Place a stack unit in the offline state.
S5000
Syntax
offline stack-unit unit-number
Parameters
stack-unit unit-
number
Enter the keywords stack-unit followed by the unit
number. The range is 0 to 11.
Defaults none
Command
Modes
EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This is an automatic
process. A warning message appears when the offline stack-unit command
is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands
show environment – views the S5000 component status (for example,
temperature, voltage).
online stack-unit
Place a stack unit in the online state.
S5000
Syntax
online stack-unit unit-number
Parameters
stack-unit unit-
number
Enter the keywords stack-unit followed by the unit
number. The range is 0 to 11.
Defaults none
Command
Modes
EXEC Privilege
Debugging and Diagnostics
1403