Use this command to minimize the time required for the VLT system to determine
the unit ID assigned to each peer switch when one peer reboots.
vlt domain
Use this command to enable VLT on a switch, configure a VLT domain, enter VLT-domain configuration
mode, set a VLT port delay time, set VLT priorities and configure a VLT peer link.
S5000
Syntax
vlt domain domain-id
Parameters
domain-id Enter the Domain ID number. You must configure the same
domain ID on the peer switch. VLT uses the domain ID to
automatically create a VLT MAC address for the domain. The
range of domain IDs is 1 to 1000.
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The VLT domain ID must be the same between the two VLT devices. If the domain
ID is not the same, a syslog message is generated and VLT does not launch.
Related
Commands
show vlt – uses the show vlt brief command to display the delay-restore
value.
vlt-peer-lag port-channel
Associate the port channel to the corresponding port channel in the VLT peer for the VLT connection to
an attached device.
S5000
Syntax
vlt-peer-lag port-channel id-number
Parameters
id-number Enter the port-channel number that connects to another
port channel in the VLT peer.
Defaults Not configured.
Command
Modes
INTERFACE PORT-CHANNEL