Reference Guide
Parameters
number Enter the hexadecimal number as the stackable VLAN tag.
You may specify both bytes of the 2-byte S-Tag TPID. The
range is 0 to FFFF. The default is 9100.
Defaults 0x9100
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
For specific interoperability limitations regarding the S-Tag TPID, refer to the Dell
Networking OS Configuration Guide.
The four characters you enter in the CLI for number are interpreted, as shown
below:
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related
Commands
portmode hybrid – sets a port (physical ports only) to accept both tagged and
untagged frames. A port configured this way is identified as a hybrid port in report
displays.
vlan-stack trunk – specifies a Layer 2 port or port channel as a trunk port to the
Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
S5000
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-
stack trunk command.
Defaults Not configured.
Command
Modes
INTERFACE
VLAN Stacking
1367