Reference Guide

Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
You can assign physical port or port-channel interfaces to an uplink-state group.
You can assign an interface to only one uplink-state group. You must configure
each interface assigned to an uplink-state group as either an upstream or
downstream interface, but not both.
You can assign individual member ports of a port channel to the group. An uplink-
state group can contain either the member ports of a port channel or the port
channel itself, but not both.
Related
Commands
upstream – assigns a port or port-channel to the uplink-state group as an
upstream interface.
uplink-state-group – creates an uplink-state group and enables the tracking of
upstream links.
downstream auto-recover
Enable auto-recovery so that UFD-disabled downstream ports in an uplink-state group automatically
come up when a disabled upstream port in the group comes back up.
S5000
Syntax
downstream auto-recover
To disable auto-recovery on downstream links, use the no downstream auto-
recover command.
Defaults The auto-recovery of UFD-disabled downstream ports is enabled.
Command
Modes
UPLINK-STATE-GROUP
Command
History
Version 9.0(1.3) Introduced on the S5000.
Related
Commands
downstream – assigns a port or port-channel to the uplink-state group as a
downstream interface.
uplink-state-group – creates an uplink-state group and enables the tracking of
upstream links.
1352
Uplink Failure Detection (UFD)