Reference Guide

Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed
interface state to down: Te 4/23
Dell#Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-5-OSTATE_DN:
Changed interface state to down: Po 102
Apr 8 10:22:44: %STKUNIT3-M:CP %IFMGR-1-DEL_PORT: Removed
port: Te 4/0-3,16-47, Fo 4/48,52,60,
Apr 8 10:22:44: %STKUNIT3-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack
unit 4 down - reset
Apr 8 10:22:44: %STKUNIT2-S:CP %IFMGR-1-DEL_PORT: Removed
port: Te 4/0-3,16-47, Fo 4/48,52,60,
Apr 8 10:22:50: %S5000:3 %IFAGT-5-STACK_PORT_LINK_DOWN:
Changed stack port state to down: 3/12
Related
Commands
reload – reboots Dell Networking OS.
upgrade system (stack unit) – synchronizes the Dell Networking OS image
running on an S5000 stack unit from the master switch.
show redundancy
Display the current redundancy configuration (status of automatic reboot configuration on stack
management unit).
S5000
Syntax
show redundancy
Command
Modes
EXEC
EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Example
Dell#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 4
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 9.0(1.3)
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 3
Stack-unit SW Version: 9.0(1.0)
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Stacking Commands
1311