Reference Guide

55
Stacking Commands
All commands in this chapter are specific to the Dell Networking OS on the S5000 switch.
The commands are always available and operational. You can use the commands to pre-configure a
switch so that the configuration settings are invoked when the switch is attached to other S5000 units.
For information about using the S5000 stacking feature, refer to the Stacking chapter in the Dell
Networking OS Configuration Guide for the S5000.
CAUTION: You cannot enable S5000 stacking simultaneously with virtual link trunking (VLT). If
you enable both at the same time, unexpected behavior occurs.
redundancy disable-auto-reboot stack-unit
Prevent the S5000 stack management unit, stack member unit, and standby unit from rebooting if they
fail.
S5000
Syntax
redundancy disable-auto-reboot stack-unit [members | 0-11]
To re-enable the automatic reboot of a failed stack unit, use the no redundancy
disable-auto-reboot stack-unit command.
Defaults Disabled (a failed switch automatically reboots).
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The range is 0 to 11. Entering this command disables the automatic reboot and
keeps a failed stack unit in the Failed state. A failed switch does not reboot until you
manually reload it. The disabling of the automatic reboot is displayed in the
running-config.
Related
Commands
show redundancy – displays the current redundancy status.
Stacking Commands
1309