Reference Guide
Parameters
view-name Enter the name of the view (not to exceed 20 characters).
oid-tree Enter the OID sub tree for the view (not to exceed 20
characters).
included (OPTIONAL) Enter the keyword included to include the MIB
family in the view.
excluded (OPTIONAL) Enter the keyword excluded to exclude the
MIB family in the view.
Defaults none
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The oid-tree variable is a full sub-tree starting from 1.3.6 and can not specify the
name of a sub-tree or a MIB. The following Example configures a view named
rview that allows access to all objects under 1.3.6.1.
Example
Dell# conf
Dell#(conf) snmp-server view rview 1.3.6.1 included
Related
Commands
show running-config snmp – displays the SNMP running configuration.
snmp trap link-status
Enable the interface to send SNMP link traps, which indicate whether the interface is up or down.
S5000
Syntax
snmp trap link-status
To disable sending link trap messages, use the no snmp trap link-status
command.
Defaults Enabled.
Command
Modes
INTERFACE
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
If the interface is expected to flap during normal usage, you could disable this
command.
Simple Network Management Protocol (SNMP) and Syslog
1283