Reference Guide
sflow extended-switch enable
Enable packing information on a switch only.
S5000
Syntax
sflow extended-switch enable
To disable packing information, use the no sflow extended-switch [enable]
command.
Parameters
enable Enter the keyword enable to enable global extended
information.
Defaults Disabled.
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Related
Commands
show sflow – displays the sFlow configuration.
sflow polling-interval (Global)
Set the sFlow polling interval at a global level.
S5000
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval
command.
Parameters
interval value Enter the interval value in seconds. The range is 15 to 86400
seconds. The default is 20 seconds.
Defaults 20 seconds
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The polling interval for an interface is the maximum number of seconds between
successive samples of counters to be sent to the collector. This command changes
the global default counter polling (20 seconds) interval. You can configure an
interface to use a different polling interval.
1260
sFlow