Reference Guide

Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
rmon hc-alarm
Set an alarm on any MIB object.
S5000
Syntax
rmon hc-alarm number variable interval {delta | absolute}
rising-threshold value event-number falling-threshold value
event-number [owner string]
To disable the alarm, use the no rmon hc-alarm number command.
Parameters
number Enter the alarm integer number from 1 to 65535. The value
must be unique in the RMON alarm table.
variable The MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object
type must be a 64 bit integer.
interval Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is 5 to 3600 seconds.
delta Enter the keyword delta to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute Enter the keyword absolute to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
rising-
threshold value
event-number
Enter the keywords rising-threshold followed by the
value (64 bit) the rising-threshold alarm is either triggered or
reset. Then enter the event-number to trigger when the
rising threshold exceeds its limit. This value is the same as
the alarmRisingEventIndex or alarmTable of the RMON MIB.
If there is no corresponding rising-threshold event, the value
is zero.
falling-
threshold value
event-number
Enter the keywords falling-threshold followed by the
value (64 bit) the falling-threshold alarm is either triggered or
reset. Then enter the event-number to trigger when the
falling threshold exceeds its limit. This value is the same as
the alarmFallingEventIndex or the alarmTable of the RMON
Remote Monitoring (RMON)
1173