Reference Guide
rmon collection history
Enable the RMON MIB history group of statistics collection on an interface.
S5000
Syntax
rmon collection history {controlEntry integer} [owner name]
[buckets number] [interval seconds]
To remove a specified RMON history group of statistics collection, use the no
rmon collection history {controlEntry integer} command.
Parameters
controlEntry
integer
Enter the keyword controlEntry to specify the RMON
group of statistics using a value. Then enter an integer value
from 1 to 65535 that identifies the RMON group of statistics.
The integer value must be a unique index in the RMON
history table.
owner name (OPTIONAL) Enter the keyword owner followed by the
owner name to record the owner of the RMON group of
statistics.
buckets
number
(OPTIONAL) Enter the keyword buckets followed the
number of buckets for the RMON collection history group of
statistics. The bucket range is 1 to 1000. The default is 50.
interval
seconds
(OPTIONAL) Enter the keyword interval followed the
number of seconds in each polling cycle. The range is 5 to
3600 seconds. The default is
1800 seconds.
Defaults none
Command
Modes
CONFIGURATION INTERFACE (config-if)
Command
History
Version 9.0(1.3) Introduced on the S5000.
rmon collection statistics
Enable RMON MIB statistics collection on an interface.
S5000
Syntax
rmon collection statistics {controlEntry integer} [owner name]
To remove RMON MIB statistics collection on an interface, use the no rmon
collection statistics {controlEntry integer} command.
Remote Monitoring (RMON)
1171