Reference Guide
variable Enter the MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3. The object
type must be a 32 bit integer.
interval Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is 5 to 3600 seconds.
delta Enter the keyword delta to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute Enter the keyword absolute to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
rising-
threshold value
event-number
Enter the keywords rising-threshold followed by the
value (32 bit) the rising-threshold alarm is either triggered or
reset. Then enter the event-number to trigger when the
rising threshold exceeds its limit. This value is the same as
the alarmRisingEventIndex or alarmTable of the RMON MIB.
If there is no corresponding rising-threshold event, the value
is zero.
falling-
threshold value
event-number
Enter the keywords falling-threshold followed by the
value (32 bit) the falling-threshold alarm is either triggered or
reset. Then enter the event-number to trigger when the
falling threshold exceeds its limit. This value is the same as
the alarmFallingEventIndex or the alarmTable of the RMON
MIB. If there is no corresponding falling-threshold event, the
value is zero.
owner string (OPTIONAL) Enter the keyword owner followed by the
owner name to specify an owner for the alarm. This is the
alarmOwner object in the alarmTable of the RMON MIB.
Defaults owner
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
1170
Remote Monitoring (RMON)