Reference Guide

Parameters
debug (OPTIONAL) Enter the keyword debug to add timestamps to
debug messages.
log (OPTIONAL) Enter the keyword log to add timestamps to
log messages with severity 0 to 6.
datetime (OPTIONAL) Enter the keyword datetime to have the
current time and date added to the message.
localtime (OPTIONAL) Enter the keyword localtime to include the
localtime in the timestamp.
msec (OPTIONAL) Enter the keyword msec to include milliseconds
in the timestamp.
show-
timezone
(OPTIONAL) Enter the keyword show-timezone to include
the time zone information in the timestamp.
uptime (OPTIONAL) Enter the keyword uptime to have the
timestamp based on time elapsed since system reboot.
Defaults Not configured.
Command
Modes
CONFIGURATION
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service
timestamps debug uptime in the running-configuration.
Use the show running-config command to view the current options set for the
service timestamps command.
show alarms
View alarms for the stack-unit, switch, and fan trays.
S5000
Syntax
show alarms [threshold]
Parameters
threshold (OPTIONAL) Enter the keyword threshold to display the
temperature thresholds set for the stack-unit.
Command
Modes
EXEC
EXEC Privilege
Control and Monitoring
107