Users Guide
FCoE map applied on the port starts sending FIP multicast advertisements using the parameters in the
FCoE map over server-facing Ethernet ports. A server sees the FC port with its applied FCoE map as an
FCF port.
Example
Dell(conf)#interface fibrechannel 3/0
Dell(conf-if-fc-3/0)#exit#
Related
Commands
show interfaces fibrechannel — displays the configuration of a Fibre Channel interface.
show interfaces fibrechannel
Display the configuration of a Fibre Channel interface.
S5000
Syntax
show interfaces fibrechannel type slot/port
Parameters
fibrechannel
slot
/
port
Enter the keyword FibreChannel then the slot/port numbers. Valid slot numbers
are from 0 to 11. The port range is from 0 to 47.
Command Modes
● EXEC
● EXEC Privilege
Command
History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
Use the show interfaces fibrechannel command to display the current configuration and
operation of a Fibre Channel port on the S5000.
NOTE: In release 9.0.(1.3), an FC module can be installed only in expansion slot 0 (ports 0 to 11) on
an S5000 switch.
The following table describes the show interfaces fibrechannel command output shown in the
following example.
Table 1. Output Fields for the show interfaces fibrechannel Command
Field Description
Information:
Fibrechannel 0/0 is down, FC link is down Administrative state of the
Fibre Channel interface
(up/enabled or down/
shutdown) and operational
state of the FC link (up or
down)
.
Pluggable media present, SFP+ type Pluggable optic is inserted
in the port or not, and the
SFP+ optic type
.
Wavelength Wavelength of the
inserted optic
.
SFP+ receive power Power received on SFP+
optic
.
Interface index Index number of FC port.
Fibre Channel Interface Commands 715